Water cut formula for oil and gas wells
Last updated November 20, 2026 by WellersDen
Quick answer
Water cut is the share of the produced liquid that is water, by volume. Gas is not part of it.
Both volumes must cover the same period and be in the same unit; the unit then cancels. A well that makes 224 bbl of water and 96 bbl of oil on test has a water cut of 70%.
On this page
Water cut calculator
Enter your own volumes. It runs in your browser, and the numbers you enter are not sent anywhere.
The formula and its relatives
The same two volumes give three numbers that people use for the same idea:
With water cut written as a fraction (0.70, not 70), the two convert directly:
Rates work as well as volumes. Water rate divided by total liquid rate gives the same water cut, because the test duration cancels.
Worked example
Assumptions: an 8-hour test through a three-phase separator. The oil figure is net oil at stock-tank conditions. The water figure is all the water produced: free water from the water leg plus the water carried in the oil leg.
- Oil produced: 96 STB
- Water produced: 224 bbl
Step 1: total liquid
Step 2: water cut
Step 3: oil cut and WOR
Step 4: check it against the daily rates
Surface or line conditions: say which
Production reporting normally states water cut at surface conditions: oil in stock-tank barrels, water in barrels. A water-cut meter or multiphase meter reads at line conditions instead, where the oil still holds dissolved gas and takes up more volume. The water cut at line conditions is therefore a little lower than the reported one.
Take the example above with a shrinkage factor of 0.95 between the separator and the stock tank. The 96 STB of oil occupied 101.05 bbl at separator conditions:
Neither is wrong, but they are not the same number. State the basis when comparing a meter reading with a test report. For what changes between the two, see stock tank barrel vs barrel.
Water cut is a volume ratio by default. A mass-based water fraction is a different number, because water is denser than oil.
Why accuracy matters most at high water cut
Oil rate is usually worked out as liquid rate times oil cut, so a small error in water cut becomes a large error in oil once the well is mostly water. At 1,000 bbl/day of liquid:
One point of water cut is 20% of the oil. At 20% water cut the same one-point error would move the oil rate by a little over 1%.
Water cut is not BS&W
A centrifuge reading on a sample from the oil leg tells you how much water and sediment is still in that oil. It leaves out the free water the separator already removed, so it is far lower than the well's water cut. The two are compared, with a worked example, in BS&W vs water cut.
Common mistakes
- Dividing by oil instead of total liquid. Water over oil is WOR. In the example that is 2.33, which is not a 70% water cut.
- Using the oil-leg BS&W as the water cut. It ignores free water.
- Leaving emulsified water in the oil. Water measured in the oil leg belongs with the water, and has to come out of the oil volume too.
- Mismatched intervals. Oil gauged over 8 hours and water metered over 24 do not make a water cut.
- Comparing line-condition and stock-tank figures as if they were on the same basis.
- Including gas. Water cut is a liquid ratio. Gas enters in GOR and GLR, not here.
- Reporting 0% when nothing was produced. With no liquid, water cut is undefined. Report N/A.
FAQ
What is the water cut formula?
Water cut (%) = water volume / (oil volume + water volume) × 100, with both volumes in the same unit and covering the same period. Water rate divided by total liquid rate gives the same result.
Is water cut calculated by volume or by mass?
By volume, unless stated otherwise. A mass-based water fraction gives a different number because water is denser than oil.
What is the difference between water cut and water-oil ratio (WOR)?
Water cut divides water by total liquid; WOR divides water by oil. As fractions, water cut = WOR / (1 + WOR). A 70% water cut is a WOR of 2.33.
Does gas affect water cut?
No. Water cut only compares water with total liquid. Gas appears in the gas-oil ratio and gas-liquid ratio. Dissolved gas does matter indirectly: oil at line conditions has more volume than stock-tank oil, so a water cut measured at line conditions is slightly lower.
What is the water cut if a well produces no liquid?
It is undefined, because the formula divides by zero. Report it as N/A, not 0%.
Get water cut with the rest of the well test
WellersDen takes the test duration and the oil, gas, and water produced, typed in or imported from a CSV file, and returns water cut together with the daily rates and GOR. The results, formulas, and assumptions go into a PDF report you can send to a client. The calculator is free and needs no account. A free account includes one PDF report.