GOR vs GLR: gas-oil ratio and gas-liquid ratio compared
Last updated November 20, 2026 by WellersDen
Quick answer
GOR (gas-oil ratio) is the gas produced divided by the oil produced. GLR (gas-liquid ratio) is the gas produced divided by the total liquid produced, oil plus water.
In a well that makes no water the two are equal. Once water arrives, GLR is always the lower number, and the gap widens as water cut rises.
On this page
Comparison table
| GOR | GLR | |
|---|---|---|
| What it measures | Gas per barrel of oil | Gas per barrel of total liquid (oil plus water) |
| Formula | Gas (scf) / Oil (STB) | Gas (scf) / (Oil + Water) (bbl) |
| Units | scf/STB, or m³/m³ | scf/bbl (often written scf/STB), or m³/m³ |
| Effect of water | None: water is not in the formula | Falls as water cut rises |
| When to use it | Reservoir fluid type, reservoir monitoring, comparison with PVT data, regulatory reporting | Flow in tubing and flowlines, artificial lift design (gas lift, plunger lift, pump gas handling), separator sizing |
How they relate
The link between them is the water cut, written as a fraction:
WOR is the water-oil ratio, water divided by oil. Both forms follow from the definitions, so if you have GOR and water cut you already have GLR.
Worked example
Assumptions: a stabilised 24-hour test on a naturally flowing well, so all the gas is formation gas. Oil is in stock-tank barrels, water in barrels, and gas in scf at standard conditions.
- Oil: 150 STB/day
- Water: 350 bbl/day
- Gas: 120,000 scf/day (120 Mscf/day)
Step 1: GOR
Step 2: GLR
Step 3: check with water cut
Same well, same test: a GOR of 800 and a GLR of 240. Quoting one where the other is expected is an error of more than a factor of three here.
Gas lift adds two more ratios
On a gas-lifted well, the gas at the separator is formation gas plus the lift gas that was injected. That gives three GLRs, and they should be named:
- Formation GLR: formation gas over total liquid.
- Injection GLR: injected gas over total liquid.
- Total GLR: all gas above the injection point over total liquid. This is what the tubing sees.
Put the example well on gas lift with 300 Mscf/day of injection. The separator now meters 420 Mscf/day.
GOR is a property of what the reservoir produces, so it uses formation gas only. It is still 800 scf/STB. Dividing the separator gas by the oil instead gives 2,800 scf/STB, which describes nothing in the reservoir.
Which one to use
Use GOR for the reservoir
GOR tells you about the fluid and the reservoir: what type of oil it is, whether pressure has fallen below the bubble point, whether gas-cap gas has reached the well. Water has no place in those questions, which is why it is left out. The calculation and its variants are in how to calculate GOR.
Use GLR for the wellbore and the facility
The tubing does not care which liquid it is lifting. Pressure-drop correlations, gas-lift design, and separator sizing all work on gas per barrel of total liquid. Plunger lift is a typical case: a commonly quoted rule of thumb asks for about 400 scf/bbl of GLR for every 1,000 ft of depth. It is a screening guide, not a design method, and it is stated in GLR, not GOR.
Gas wells flip the ratio
For gas and gas-condensate wells the liquid is the minor phase, so the ratio is usually turned over: condensate-gas ratio (CGR) or liquid-gas ratio (LGR), in STB/MMscf.
Common mistakes
- Mixing up GOR and GLR. Feeding a GOR into a lift or flow calculation that expects GLR overstates the gas per barrel of liquid by a factor of 1 / (1 - water cut). At 70% water cut that is 3.33 times too much gas.
- Counting lift gas as formation gas. Subtract the injected volume before calculating GOR or formation GLR.
- Trusting the unit label. GLR is often written in scf/STB even though the denominator includes water. Check the definition, not the unit.
- Reading reservoir behaviour from a GLR trend. GLR falls when water cut rises even if GOR has not moved. Track GOR for the reservoir.
- Using oil at separator conditions. The oil in both ratios is stock-tank oil. See stock tank barrel vs barrel.
- Mismatched intervals. Gas, oil, and water must cover the same period.
FAQ
What is the difference between GOR and GLR?
GOR divides the gas produced by the oil produced. GLR divides the same gas by the total liquid, oil plus water. They are equal only when the well makes no water.
How do you convert GOR to GLR?
Multiply GOR by (1 - water cut), with water cut as a fraction, or divide GOR by (1 + WOR). A GOR of 800 scf/STB at 70% water cut is a GLR of 240 scf/bbl.
Is GLR always lower than GOR?
It is lower whenever the well produces water, and equal when it produces none. It can never be higher, because the denominator of GLR includes everything in the denominator of GOR plus the water.
Which is used for gas lift design, GOR or GLR?
GLR. Lift design works on gas per barrel of total liquid, and separates formation GLR, injection GLR, and total GLR. GOR is still reported, using formation gas only.
What units are GOR and GLR measured in?
GOR is in scf/STB. GLR is in scf/bbl, where the barrels are oil plus water, though it is often labelled scf/STB. Both are m³/m³ in metric units.
Get GOR, water cut, and liquid rate from one test
WellersDen takes the test duration and the oil, gas, and water produced, typed in or imported from a CSV file, and returns GOR, water cut, and the gas and total liquid rates. GLR is not a separate line in the results yet; it is GOR × (1 - water cut), or gas rate over total liquid rate, from the same report. The results, formulas, and assumptions go into a PDF report you can send to a client. The calculator is free and needs no account. A free account includes one PDF report.