Stock tank barrel vs barrel: STB and bbl compared
Last updated November 20, 2026 by WellersDen
Quick answer
A barrel (bbl) is a unit of volume: 42 US gallons, about 0.159 m³, at whatever pressure and temperature the liquid happens to be. A stock tank barrel (STB) is one barrel of oil at stock-tank conditions, normally taken as 60 °F and atmospheric pressure (14.696 psia), after the dissolved gas has come out of it.
The two are the same size. What differs is the condition of the oil. The same oil takes up more barrels in the reservoir or in a separator than it does in the stock tank, so a metered volume in bbl has to be corrected before it can be called STB.
On this page
Comparison table
| Barrel (bbl) | Stock tank barrel (STB) | Reservoir barrel (RB) | |
|---|---|---|---|
| What it measures | A volume of any liquid | Oil volume at stock-tank conditions, with the solution gas removed | Oil plus its dissolved gas at reservoir pressure and temperature |
| Conditions | Whatever they were when measured; they need stating | 60 °F and 14.696 psia (15 °C and 101.325 kPa in metric practice) | Reservoir pressure and temperature |
| Formula | 1 bbl = 42 US gal = 0.158987 m³ = 5.6146 ft³ | STB = oil at separator conditions (bbl) × shrinkage factor = RB / Bo | RB = STB × Bo |
| Units | bbl, bbl/day | STB, STB/day | RB or res bbl, RB/day |
| When to use it | Water volumes, total liquid, raw meter and tank readings, vessel capacities | Oil rates, GOR, sales, reserves, and anything reported outside the facility | Material balance, voidage, and other reservoir calculations |
Why the same oil has different volumes
- Gas comes out. Oil under pressure holds dissolved gas. As pressure drops from the reservoir to the separator to the tank, that gas leaves and the liquid shrinks. This is the main effect.
- It cools. Oil contracts as it cools to 60 °F.
- Pressure itself has a small effect, because liquid oil is only slightly compressible.
The oil formation volume factor, Bo, is the ratio of reservoir barrels to stock tank barrels. It is greater than 1. With a Bo of 1.25 RB/STB, 1,000 STB at surface was 1,250 RB in the reservoir. Bo runs from the reservoir to the stock tank; the shrinkage factor used in a well test covers the shorter step from the separator to the stock tank. They are not interchangeable.
Converting a metered volume to STB
- Meter factor corrects the meter reading to true volume, from a proving or calibration.
- BS&W, as a fraction, removes the water and sediment still in the oil stream. See BS&W vs water cut.
- Shrinkage factor is stock-tank volume divided by volume at meter conditions, from a shrinkage tester, a flash calculation, or PVT data.
Conventions vary in two places, so check which one a procedure uses:
- Shrinkage is quoted either as the fraction remaining (0.95) or as the fraction lost (5%). Multiplying by 0.05 instead of 0.95 is an easy way to lose most of the oil.
- Some procedures fold the temperature correction to 60 °F into the shrinkage factor. Others apply a separate volume correction factor from the API tables (API MPMS Chapter 11.1). Apply it once.
Worked example
Assumptions: a test separator running at 150 psig and 110 °F. The oil-leg meter has a meter factor of 1.000. The shrinkage factor was measured at separator conditions and already includes the temperature correction to 60 °F.
- Oil-leg meter: 520 bbl
- BS&W of the oil leg: 0.8%
- Shrinkage factor: 0.95
- Gas produced: 370,000 scf
Step 1: take out the water and sediment
Step 2: apply the shrinkage factor
Step 3: see what it does to GOR
Using the raw reading understates GOR by 5.8% and overstates the oil volume by 29.95 bbl. The full method is in how to calculate GOR.
Is "standard" the same as "stock tank"?
In everyday use, yes: STB means oil at 60 °F and atmospheric pressure. Three details are worth knowing.
- A real stock tank sits at ambient temperature, not 60 °F. The gauged volume is corrected to 60 °F.
- Custody transfer uses stricter terms. Gross observed volume is corrected for temperature to gross standard volume, and deducting sediment and water gives net standard volume. Net standard volume is the closest match to STB of oil.
- Stock-tank volume depends on the path. The same reservoir oil yields slightly different stock-tank volumes, and different GOR, depending on separator pressure and the number of separation stages.
What about water and gas?
Water is normally reported in plain barrels. It holds very little gas, so its volume barely changes between the separator and the surface. Gas uses the same idea as STB under a different name: a standard cubic foot (scf) is a cubic foot of gas at the stated base pressure and temperature.
Common mistakes
- Using bbl where STB is needed. Oil rates, GOR, and reserves are defined on stock-tank oil. A separator or multiphase meter reading in bbl/day is not STB/day.
- Applying shrinkage the wrong way round, or twice: once in the flow computer and again in the spreadsheet.
- Using Bo as the separator shrinkage. Bo includes the gas released between the reservoir and the separator, so 1/Bo overcorrects a separator volume.
- Skipping the BS&W deduction. The water in the oil leg is not oil.
- Adding STB of oil to bbl of water without saying so. A total liquid rate at surface conditions is common and useful, but it is a sum of volumes at surface, not the liquid volume in the flowline. The same care applies to a water cut quoted at line conditions.
FAQ
Is a stock tank barrel bigger than a barrel?
No. Both are 42 US gallons. STB adds a condition: the oil is measured at stock-tank conditions, normally 60 °F and atmospheric pressure, after its dissolved gas has come out.
What are stock-tank conditions?
Normally 60 °F and atmospheric pressure (14.696 psia). Metric practice commonly uses 15 °C and 101.325 kPa. A real tank is at ambient temperature, so gauged volumes are corrected to the standard temperature.
How do I convert bbl to STB?
Multiply the metered oil volume by the meter factor, by (1 - BS&W) to remove water and sediment, and by the shrinkage factor for the step from meter conditions to the stock tank. There is no fixed conversion factor; shrinkage depends on the oil and the separator conditions.
What is the difference between a stock tank barrel and a reservoir barrel?
A reservoir barrel is oil with its dissolved gas at reservoir pressure and temperature. A stock tank barrel is the oil left at surface. They are related by the oil formation volume factor: RB = STB × Bo. With a Bo of 1.25, 1,000 STB is 1,250 RB.
Why is GOR quoted in scf/STB and not scf/bbl?
Because the ratio only means something if both volumes are at defined conditions: gas at standard conditions and oil at stock-tank conditions. Dividing by oil at separator conditions gives a lower number that changes with separator pressure.
Once the oil is in STB
WellersDen does not apply meter, BS&W, or shrinkage corrections; it expects oil already in STB, gas in scf, and water in bbl. From those and the test duration it returns the daily rates, water cut, and GOR, and puts them in a PDF report with the units and assumptions stated on it. The calculator is free and needs no account. A free account includes one PDF report.