# WellersDen > WellersDen is a calculator for oil and gas well tests. Enter the test duration and the oil, gas, and water produced to get daily rates, water cut, and gas-oil ratio, and a PDF report. Website: https://wellersden.com Contact: divv@divvlaunches.com ## What it is A web calculator for basic oil and gas well-test (production test) reporting. The user enters one test and gets time-normalized production metrics. It is for petroleum engineers, well-testing professionals, and oilfield service companies. ## Inputs - Well name - Test date - Test duration, in hours (must be greater than zero) - Oil produced, in stock-tank barrels (STB) - Gas produced, in standard cubic feet (scf), already at the user's reporting standard conditions - Water produced, in barrels (bbl) All volumes must cover the same test interval. Inputs can be typed or imported from a one-record CSV file. ## Outputs and formulas - Oil rate (STB/day) = Oil volume (STB) / Test duration (hours) × 24 - Gas rate (scf/day) = Gas volume (scf) / Test duration (hours) × 24 - Gas rate (Mscf/day) = Gas rate (scf/day) / 1,000 - Water rate (bbl/day) = Water volume (bbl) / Test duration (hours) × 24 - Total liquid rate (bbl/day) = Oil rate + Water rate - Water cut (%) = Water volume / (Oil volume + Water volume) × 100 - Gas-oil ratio (scf/STB) = Gas volume (scf) / Oil volume (STB) Gas-oil ratio is reported as N/A when no oil was produced. Water cut is reported as N/A when no oil and no water were produced. ## Worked example Inputs: - Test duration: 12 hours - Oil produced: 100 STB - Gas produced: 50,000 scf - Water produced: 25 bbl Results: - Oil rate: 200 STB/day - Gas rate: 100,000 scf/day (100 Mscf/day) - Water rate: 50 bbl/day - Total liquid rate: 250 bbl/day - Water cut: 20 % - Gas-oil ratio (GOR): 500 scf/STB ## Assumptions - All entered volumes were measured over the same test interval, stated as the test duration. - Oil volume is entered in stock-tank barrels (STB) and water volume in barrels (bbl). - Gas volume is entered in standard cubic feet (scf), already expressed at the user's reporting standard conditions. No pressure, temperature, or compressibility correction is applied, and raw meter or reservoir-condition volumes are not converted. - Rates are time-normalized volumes scaled to a 24-hour day. They represent the average rate over the test interval, not a stabilized-rate determination. - Total liquid rate adds the oil rate (STB/day) and water rate (bbl/day) directly, with no shrinkage or formation volume factor adjustment. - 1 Mscf = 1,000 scf. - Water cut is reported as N/A when no liquid was produced. Gas-oil ratio is reported as N/A when no oil was produced. - Values are calculated at full precision and rounded to 2 decimal places for display only. ## What it does not do WellersDen does not perform pressure transient analysis, fluid property correction, meter calibration, or reservoir interpretation. These results are preliminary and are not certified engineering calculations. They require review by a qualified engineer and independent verification before being used for operational, commercial, regulatory, or safety-critical decisions. ## CSV import format One header row and exactly one data row. All six columns are required, in any order. Numbers are plain decimals with no thousands separators. ``` well_name,test_date,duration_hours,oil_stb,gas_scf,water_bbl WD-001,2026-01-15,12,100,50000,25 ``` ## Pricing - Free: the calculator, results, and CSV import, with no account needed. A free account also includes 3 AI-written summaries and one PDF report. - WellersDen Pro: $29 per month, plus tax where it applies. Unlimited PDF reports (inputs, results, formulas, assumptions, disclaimer) and unlimited AI-written summaries. Payments are processed by Dodo Payments. Cancel any time from the account menu. Payments are non-refundable, except for charges made in error or where the law requires a refund. ## Privacy in brief Calculations and PDF generation run in the browser, so measurements are not sent to WellersDen's servers. The exception is the AI summary: when requested, that test's data is sent to the server and to the AI provider to write it, and is not stored. Details: https://wellersden.com/privacy ## Pages - [Calculator](https://wellersden.com/): The well-test calculator, pricing, formulas, and CSV format. - [Free tools](https://wellersden.com/tools): Free single-purpose oilfield calculators. - [Water cut calculator](https://wellersden.com/tools/water-cut-calculator): Calculate water cut, oil cut, and water-oil ratio from the oil and water volumes produced over the same period. - [Gas-oil ratio (GOR) calculator](https://wellersden.com/tools/gor-calculator): Calculate the produced gas-oil ratio in scf/STB from the gas and oil volumes produced over the same period. - [Well test rate calculator](https://wellersden.com/tools/well-test-rate-calculator): Convert a volume produced during a test of any length into a rate per day and per hour. - [Oil barrel converter](https://wellersden.com/tools/barrel-converter): Convert oil barrels (bbl) to cubic metres, litres, US gallons, and cubic feet using the exact definitions. - [Gas volume converter: scf, Mscf, MMscf, m³](https://wellersden.com/tools/gas-volume-converter): Convert a gas volume in cubic feet to Mscf, MMscf, and cubic metres. - [Guides](https://wellersden.com/guides): Formulas, units, and worked examples for well-test calculations. - [How to calculate GOR (gas-oil ratio) in oil and gas](https://wellersden.com/guides/how-to-calculate-gor): GOR is gas volume in scf divided by oil volume in STB. The formula, a worked well-test example, unit conversions, a calculator, and the usual mistakes. - [Water cut formula for oil and gas wells](https://wellersden.com/guides/water-cut-formula): Water cut (%) = water / (oil + water) × 100. The formula with units, a worked well-test example, how it relates to WOR, a calculator, and common mistakes. - [Stock tank barrel vs barrel: STB and bbl compared](https://wellersden.com/guides/stock-tank-barrel-vs-barrel): A barrel (bbl) is 42 US gallons at any conditions. A stock tank barrel (STB) is oil at 60 °F and atmospheric pressure. How to convert, with an example. - [BS&W vs water cut: what each one measures](https://wellersden.com/guides/bsw-vs-water-cut): BS&W is the water and sediment in a sample of oil. Water cut is the water in all the liquid a well produces. A comparison table and a worked example. - [GOR vs GLR: gas-oil ratio and gas-liquid ratio compared](https://wellersden.com/guides/gor-vs-glr): GOR is gas divided by oil. GLR is gas divided by oil plus water. A comparison table, the formula linking them through water cut, and a worked example. - [Blog](https://wellersden.com/blog): Product notes and updates. - [Introducing WellersDen](https://wellersden.com/blog/introducing-wellersden): A small tool that turns well-test measurements into production rates and a shareable report, without the spreadsheet. - [How long should a well test run?](https://wellersden.com/blog/how-long-should-a-well-test-run): How long to run a production well test: regulatory minimums, when a well is stable, and why the test must cover whole flow cycles. - [Contact](https://wellersden.com/contact): Email divv@divvlaunches.com. - [Terms and Conditions](https://wellersden.com/terms): Terms of use, subscription, and disclaimers. - [Privacy Policy](https://wellersden.com/privacy): What data is handled and who receives it.